Comparison operators test a relation on two operands and are considered
to represent a machine-dependent nonzero value described by, but not
necessarily equal to, STORE_FLAG_VALUE
(see section Miscellaneous Parameters)
if the relation holds, or zero if it does not. The mode of the
comparison operation is independent of the mode of the data being
compared. If the comparison operation is being tested (e.g., the first
operand of an if_then_else
), the mode must be VOIDmode
.
If the comparison operation is producing data to be stored in some
variable, the mode must be in class MODE_INT
. All comparison
operations producing data must use the same mode, which is
machine-specific.
There are two ways that comparison operations may be used. The
comparison operators may be used to compare the condition codes
(cc0)
against zero, as in (eq (cc0) (const_int 0))
. Such
a construct actually refers to the result of the preceding instruction
in which the condition codes were set. The instructing setting the
condition code must be adjacent to the instruction using the condition
code; only note
insns may separate them.
Alternatively, a comparison operation may directly compare two data objects. The mode of the comparison is determined by the operands; they must both be valid for a common machine mode. A comparison with both operands constant would be invalid as the machine mode could not be deduced from it, but such a comparison should never exist in RTL due to constant folding.
In the example above, if (cc0)
were last set to
(compare x y)
, the comparison operation is
identical to (eq x y)
. Usually only one style
of comparisons is supported on a particular machine, but the combine
pass will try to merge the operations to produce the eq
shown
in case it exists in the context of the particular insn involved.
Inequality comparisons come in two flavors, signed and unsigned. Thus,
there are distinct expression codes gt
and gtu
for signed and
unsigned greater-than. These can produce different results for the same
pair of integer values: for example, 1 is signed greater-than -1 but not
unsigned greater-than, because -1 when regarded as unsigned is actually
0xffffffff
which is greater than 1.
The signed comparisons are also used for floating point values. Floating point comparisons are distinguished by the machine modes of the operands.
(eq:m x y)
(ne:m x y)
(gt:m x y)
(gtu:m x y)
gt
but does unsigned comparison, on fixed-point numbers only.
(lt:m x y)
(ltu:m x y)
gt
and gtu
but test for "less than".
(ge:m x y)
(geu:m x y)
gt
and gtu
but test for "greater than or equal".
(le:m x y)
(leu:m x y)
gt
and gtu
but test for "less than or equal".
(if_then_else cond then else)
if_then_else
expressions are valid only
to express conditional jumps.
(cond [test1 value1 test2 value2 ...] default)
if_then_else
, but more general. Each of test1,
test2, ... is performed in turn. The result of this expression is
the value corresponding to the first non-zero test, or default if
none of the tests are non-zero expressions.
This is currently not valid for instruction patterns and is supported only
for insn attributes. See section Instruction Attributes.
Go to the first, previous, next, last section, table of contents.